Contact us For registered customers Lietuvių По-русски
BASEC DNVGL

BS 7211 flat

Choose specification
Number of cores:
Choose cross-sectional area, mm²:

BS 7211 flat

These cables are suitable for fixed installation particularly for situations in which low emission smoke and domestic wiring cable for the surface wiring of sockets and lighting where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Can be installed in fixed installations in dry or damp premises on walls, boards or trays, in channels or embedded in plaster. Suitable for laying in conduit or trucking where mechanical protection is required

Solid or stranded conductor is made from annealed copper wires.

 

Additional information

The cable conformed to the EU Directive 2011/65/EU on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment.

The cable conformed to the Low Voltage EU Directive 2014/35/EC

The cable conformed with Regulation (EU) No 305/2011 of the European Parliament and of the Council.

Reaction to Fire Class Eca. DoP (Declaration of Performance LK-DoP 13/001/EN)

Technical date
Conductor resistance at +20°C In accordance with IEC 60228
Conductor working temeprature, max. +90°C (under normal conditions) + 250°C (in the event of short circuit for 5s)
Thermal shock 1 h at +150°C
Rated voltage U/U0 300/500 V
High voltage test, kV 2,5 kV
Minimum bending radius > 5 times the cable diameter
Operating temperatures Mounting +5°C - +40°C Operating -30°C - +90°C
Flame propagation Flame test in accordance with BS EN 60332-1-2
Construction
Conductors Solid (1-2,5 mm2), class 1 Stranded (4-16 mm2), class 2 in accordance with IEC 60228
Insuliation Thermosetting core insulation type GP 8, in accordance with BS 7655-1-3
Core colours In accordance with BS 7211
Sheath LSOH sheath, type LTS 2 in accordance with BS 7655-6-1
Sheath colour In accordance with BS 7211

See also


H05V-K

The cable is designed for fixed installation, in mounted or fixed on surface conduits or…


RKKB

The cord-cable is designed to use in devices where voltage does not exceed 100 V.…

© 1958 - 2021 AB „Lietkabelis“. All rights reserved. Created by A-GAIN